Radiation Detection Lab.
- Geiger Counting
Operating Plateau for the Geiger Tube
Half-Life Determination
Resolving-Time Corrections for the Geiger Counter
- Gamma-Ray Spectroscopy Using NaI(Tl)
Energy Calibration
Energy Analysis of an Unknown Gamma Source
Spectrum Analysis of 60Co and 137Cs
Energy Resolution
- Activity of a Gamma Emitter (Relative Method)
Activity of a Gamma Emitter (Absolute Method)
Mass Absorption Coefficient
The Linear Gate in Gamma-Ray Spectroscopy
Sum Peak Analysis
Photoelectric Absorption
- Activity of a Gamma Emitter (Relative Method)
Activity of a Gamma Emitter (Absolute Method)
Mass Absorption Coefficient
The Linear Gate in Gamma-Ray Spectroscopy
Sum Peak Analysis
- Alpha Spectroscopy with Surface Barrier Detectors
Simple Alpha Spectrum and Energy Calibration with a Pulser
Energy Determination of an Unknown Alpha Source
Energy Calibration with Two Alpha Sources
- Alpha Spectroscopy with Surface Barrier Detectors
Simple Alpha Spectrum and Energy Calibration with a Pulser
Energy Determination of an Unknown Alpha Source
- Energy Calibration with Two Alpha Sources
Absolute Activity of an Alpha Source
Spectrum Expansion with a Biased Amplifier
Decay Ratios for 241Am
- Energy Loss of Charged Particles (Alphas)
dE/dx for Alpha Particles in Copper Foil
dE/dx for Alpha Particles in Gas
- High-Resolution Gamma-Ray Spectroscopy
Energy Resolution with an HPGe Detector
Photopeak Efficiency for HPGe Detectors
- Escape Peaks and Efficiency for HPGe Detectors
The Response of HPGe Detectors to High-Energy Gammas
- Time Coincidence Techniques and Absolute Activity Measurements
Simple Fast Coincidence
Fast Coincidence and the Time-to-Amplitude Converter
Determination of Absolute Activity by the Coincidence Method
- Time Coincidence Techniques and Absolute Activity Measurements
Simple Fast Coincidence
Fast Coincidence and the Time-to-Amplitude Converter
- Determination of Absolute Activity by the Coincidence Method
- The Proportional Counter and Low-Energy X-Ray Measurements
Energy Calibration
Mass Absorption Coefficient for Low-Energy X Rays
- Gamma-Gamma Coincidence
Overlap Coincidence Method for Measuring Gamma-Gamma Coincidence of 22Na
- Linear Gate Method for Measuring Gamma-Gamma Coincidence of 22Na
Time-to-Amplitude Converter Method for Measuring Gamma-Gamma Coincidence of 22Na
- Nuclear Lifetimes and the Coincidence Method
Lifetime Measurement of the 14-keV State in 57Fe Using the TAC Method
Lifetime Measurement of the 14-keV State in 57Fe Using the Delayed
- Coincidence Method
Alternate Detectors to be Used with the Electronics in Experiments 14.1 and 14.2
- Neutron Activation Analysis (Slow Neutrons)
Neutron Flux Determination
Measurement of the Thermal Neutron Cross Section for the 51V(n, ?) 52V Reaction
- Determination of the Half-Life for the 27Al (n, ?) 28Al Reaction
The Saturation Factor in Neutron Activation Analysis
The Study of a Complex Sample with Two Half-Lives Present
- Thermal Neutron Shielding
The Measurement of Thermal Neutron Activation Cross Sections of Elements with High Sensitivity Ratios
- A Study of the Decay Scheme and Angular Correlation of 60Co
Verification of the Gamma-Gamma Coincidence of 60Co
Angular Correlation of 60Co